MESI mTABLET SPIRO – Wireless Digital Spirometry System (UK)
Want to know more?
The MESI mTABLET SPIRO is a wireless digital spirometer for assessing lung function in adult and paediatric patients. The handheld MESI spirometer unit sends flow and volume data wirelessly to the MESI mTABLET, a medical-grade touchscreen tablet, where results are displayed in real time. It is suitable for use at the bedside, in the consulting room or on home visits.
The spirometer uses pneumotachograph technology with integrated self-calibration, based on ambient conditions and pre-calibrated mouthpieces, so manual calibration before each session is not needed. It supports forced (FVC) and slow (SVC) vital capacity measurements, including pre- and post-bronchodilator phases for reversibility testing. Accuracy and reproducibility meet or exceed ATS/ERS standards, including the 2019 update. During testing, a real-time flow-volume curve and an incentive animation help guide the patient, and ATS acceptability and reproducibility checks flag manoeuvre quality after each blow. The system then selects the best breath automatically for a clear, consistent review.
Results are stored in MESI mRECORDS and can integrate with electronic health records. The mTABLET can also be extended with other MESI diagnostic modules, such as 12-lead ECG and ankle-brachial index.
Features:
Specifications:
Ideal for use in:
Frequently Asked Questions
Does the MESI mTABLET SPIRO need calibrating?
It uses calibration-free technology with integrated self-calibration, so manual calibration is not required. MESI still recommends regularly checking accuracy with a 3-litre calibration syringe, at least whenever a new pack of mouthpieces is opened. The MESI SPIROMD Calibration Syringe (MED/SPI/122) is available separately.
Can it be used for reversibility testing?
Yes. The FVC and SVC modes include pre- and post-bronchodilator phases.
Does it meet ATS/ERS standards?
Yes. Accuracy and reproducibility meet or exceed ATS/ERS standards, including the 2019 update, and ATS acceptability and reproducibility checks are built in.
What disposables does it need?
The spirometer is used with MESI mouthpieces. MESI SPIROMD Disposable Bacterial & Viral Filters (MED/SPI/123) are available separately.
Can I add other tests to the mTABLET?
Yes. The mTABLET can be extended with further MESI diagnostic modules, including the 12-lead ECG (MED/ECG/060) and ABI system (MED/BPM/840).